Uni-Bayreuth

Sprungmarken

 
Kracher, D; Mengelkamp, H-T; Foken, T: The Residual of the Energy Balance Closure and its Influence on the Results of three SVAT Models, Meteorologische Zeitschrift, 18, 647-661 (2009)
Abstract:
Commonly used measuring methods only enable closure of the energy balance at the earth’s surface through the use of a residual. Models inherently demand an entirely closed energy balance, which they achieve in different ways. This paper examines the effect of the residual on model simulations and the extent to which that depends on the methods used for closing the energy balance, the optimization of the parameters and the equations used. The one-dimensional surface vegetation atmosphere transfer (SVAT) models REMO, SEWAB and TERRA, which were made available by the GKSS Institute in Geesthacht, are examined and compared with measured data from the LITFASS-2003 experiment. LITFASS-2003 took place during May and June 2003 in the experimental fields of the Meteorological Observatory Lindenberg. Parameter sets optimized with regard to the turbulent fluxes yield better results, but are often not consistent with site characteristics and differ between the models. We ran the models with the optimized parameter sets, and with a set of selected parameters which correspond to the respective sites. SEWAB closes the energy balance by using an iteration of the surface temperature, through which the influence of the residual is distributed over all fluxes. In REMO and TERRA the soil heat flux is estimated as the residual from the other components of the energy balance equation. This results in an extreme overestimation of this heat flux. Parameter optimization has an impact on the partitioning of the available energy and its distribution to the turbulent heat fluxes. It does not influence the effect of the residual on the results. Currently we do not know how to close the measured energy balance at the surface propriately because of the underestimation of the turbulent fluxes by eddy-covariance measurements and the unknown partitioning of the residual between the sensible and latent heat flux. Therefore, the method SEWAB uses gives better results than the one used in REMO and TERRA. The method used to close the energy balance has more impact on the simulated surface energy balance components than does their parameterization. For this reason it is not possible to attribute the differences in the calculated heat fluxes to other differences in the equations and parameters.

Zu dieser Publikation gibt es weitere Dateien zum Download

Passwort

Letzte Änderung 05.12.2009