Liebethal, C; Foken, T: On the use of two repeatedly heated sensors in the determination of physical soil parameters, Meteorol. Zeitschrift, 15, 293-299 (2006) | |
Abstract: Variables describing the heat transport in soils are usually determined indirectly from soil temperature and/or moisture measurements. Alternatively, they can be measured using repeatedly heated sensors like the self-calibrating heat flux plate HFP01SC and the thermal properties sensor TP01 from Hukseflux (Delft, NL). This study aims to validate the data recorded with these instruments for three variables: The PHILIP correction (factor fP), the soil heat conductivity (λs), and the volumetric soil heat capacity (cv). All of these were measured in a short experiment with the HFP01SC and/or the TP01 sensor and were simultaneously calculated from reference methods using soil temperature and moisture measurements. For the data set on which this study is based, the HFP01SC's self-correction agrees with the PHILIP correction, but the sensor cannot be recommended for measuring λs. The TP01 seems to underestimate λs and should not be used to quantify cv. |
BayCEER-Kolloquium: |
---|
Do. 25.04.2024 Perspectives and challenges in the restoration and conservation of two isolated habitats: gypsum and cliffs |
BayCEER Short Courses: |
Mi. 24.04.2024 Mobile Film Making Workshop (for PhDs/PostDosc/Profs of BayCEER) |
Fr. 26.04.2024 Mobile Film Making Workshop (for students of BayCEER) |
Ökologisch-Botanischer Garten: |
Fr. 19.04.2024 aktuell Führung | Gesteine im Ökologisch-Botanischen Garten |
So. 21.04.2024 Führung | Den ÖBG kennenlernen: Allgemeine Gartenführung |